Guide · Level of development in scan to BIM

Scan to BIM LOD: Level of Development for Existing Buildings

Scan to BIM LOD (level of development) states how far you can rely on each element of a Revit model built from a laser scan. For existing buildings the useful range is LOD 200 to LOD 350: LOD 200 for generic placeholders, LOD 300 when size and location can be measured from the model, LOD 350 when the connections between elements matter for coordination. LOD 500 is not a higher step: in the 2025 BIMForum LOD Specification it marks an observed existing element whose accuracy must be stated separately.

Illustration for a scan to BIM LOD guide: a desktop monitor shows a rainbow-colored point cloud of a building interior in processing software. A laser scan like this is the base on which Revit elements are modeled to a chosen level of development. It is an illustration, not a photo of one of our projects.

Scan to BIM LOD in one paragraph

In scan to BIM, the LOD you write into the scope decides what a modeler draws on top of the point cloud and how far your team can trust each element. LOD is set per element, not per model: walls can be LOD 300 while ductwork stays LOD 200. This guide works from the 2025 edition of the BIMForum LOD Specification, the reference most US contracts point to, and applies it to buildings that already exist. If you want the scan and the model done for you, see our page on scan to BIM in Phoenix.

Level of development, defined. LOD is the degree to which a model element's geometry has been thought through, and so the degree to which people using the model may rely on it. It is not the same as level of detail, which only says how much is drawn.

What each scan to BIM LOD means, per the 2025 BIMForum spec

The BIMForum LOD Specification 2025, Part I uses the definitions from AIA Contract Document E201-2022 and adds its own explanation to each. Here they are in plain words, with what each one means when the source is a laser scan rather than a design.

LODDefinition, in shortWhat it means in scan to BIM
LOD 100A symbol or generic representation; information can be derived from other elementsRarely ordered: the point cloud already tells you more
LOD 200Generic, recognizable 3D geometry with approximate quantity, size, shape, location and orientationPlaceholders for context: equipment boxes, generic walls in areas you will not touch
LOD 300Quantity, size, shape, location and orientation can be measured from the modelThe working level for renovation design: measured walls, slabs, openings, columns, roof
LOD 350LOD 300 plus the interfaces with adjacent or dependent elements can be measuredCoordination zones: beam-to-column bearing, duct and pipe penetrations, supports you can see
LOD 400Detail sufficient for fabrication, assembly and installationSeldom possible from a scan: bolts, welds and part numbers are not visible
LOD 500An existing or as-constructed condition from observation, field verification or interpolation; accuracy must be notedDescribes where the geometry came from, not a higher detail level (see below)

Level of development vs level of detail

Level of detail is how much is drawn. Level of development is how much you can rely on what is drawn. The difference matters more for scans than for design models, because Revit families look finished the moment they are placed. A door family can show hardware and trim while sitting a few inches from the opening in the cloud. The spec is explicit: an element that is highly detailed and geometrically accurate but not located accurately can be no higher than LOD 200.

LOD requirements are minimums, and they stack

Each LOD includes the requirements of the ones below it (LOD 500 is the exception). An element is only at LOD 300 if it meets everything at 100, 200 and 300. That is useful when you check a delivered model: pick an element, measure it against the cloud, and if its location fails, its LOD drops, however much detail it carries.

The 2025 change to openings at LOD 300

Earlier editions asked LOD 300 elements to show openings with any dimension over 6 inches. The 2025 edition dropped that rule. It now asks for all planned openings in structural steel, openings that need formwork in structural concrete, and openings that need extra reinforcement in wood and cold-formed metal framing. For existing buildings, write the opening threshold you need into your scope rather than relying on the old 6-inch habit.

LOD 500 is not a step above LOD 400

Most LOD charts draw LOD 500 as the top rung, labeled "as-built" or "certified". The 2025 spec says otherwise. LOD 500 does not indicate a higher level than LOD 400. It indicates that the element's geometry was determined by observing an existing item rather than designing a future one. The definition also requires that the element's accuracy be stated, and BIMForum recommends the USIBD Level of Accuracy specification for that. The working group even chose not to write element-by-element interpretations for LOD 500, because it concerns field verification rather than modeling.

Scan to BIM LOD diagram based on the 2025 BIMForum LOD Specification. Designed elements climb from LOD 100 symbol to LOD 200 generic, LOD 300 measurable, LOD 350 interfaces and LOD 400 fabrication, each including the ones below. A separate panel shows LOD 500 for existing elements, whose geometry comes from observation or field verification and whose accuracy must be stated as an LOA.
LOD 100 to 400 describe how far a designed element is developed. LOD 500 describes an observed existing element and needs its own accuracy statement.

What this means for your scope: "LOD 500 model" is not a meaningful order on its own. Every element in a scan to BIM model is observed, so the useful question is twofold. Which LOD 200, 300 or 350 content do you need for each element, and what accuracy do you need it at?

There is no "LOD 300 model": write an LOD matrix

The spec puts it bluntly: there is no such thing as an "LOD ### model". Any model mixes elements at different levels. A request for "an LOD 300 Revit model" leaves the modeler to guess what you meant for ceilings, rooftop units, conduit and furniture. A short matrix removes the guesswork. This is a starting point for an existing commercial building; change the rows to your project.

ElementSuggested LODNote for the scope
Exterior walls, interior partitions300Modeled at measured thickness and location; state whether out-of-plumb walls are modeled plumb
Floors, slabs, slab edges300State whether slab slope or deflection is modeled or noted
Doors, windows, storefront300Sized and placed; hardware not modeled
Columns, beams, joists you can see300, or 350 where new work connectsJoists often modeled as a pattern from measured samples
Roof surface, parapets, roof drains300Needs a roof-top scan, not only interior setups
Rooftop units, major equipment200Box at measured footprint and height, with clearance zone if needed
Main ducts and pipes (visible)200 or 300Set a minimum size; smaller runs stay in the cloud
Ceilings300 for heights, 200 for gridCeiling height is often what designers need most
Concealed elementsNot modeledAnything the scanner cannot see (next section)

BIMForum publishes a Part II spreadsheet with the full element list organized by Uniformat; it is the long form of this table. For a single building, the short form above is usually enough to get comparable quotes.

LOD 200 vs 300 vs 350 vs 400 for a scanned building

The question in the secondary searches, "LOD 200 vs 300 vs 400 for scan to BIM", comes down to what you will do with the model. This table compares the four on the decisions a buyer makes.

LOD 200LOD 300LOD 350LOD 400
Can you dimension from it?No, approximateYesYes, plus connectionsYes, to fabrication detail
Typical use on existing buildingsSpace planning, context, leasing studiesRenovation design, construction documents, tenant improvementsMEP or structural coordination around existing systemsPrefabricated elements that must fit existing conditions
Can the scan support it?YesYes, for visible surfacesOnly where interfaces are visibleRarely: needs shop drawings or field inspection
Modeling effortLowestHigherHigher again, localHighest, selective

Scan to BIM LOD 200

LOD 200 elements are recognizable but approximate. Use it for everything you will not design against: neighboring tenant spaces, equipment you will keep, site context. It keeps the model light and the cost down.

Scan to BIM LOD 300

LOD 300 is the level most renovation teams mean when they say "existing conditions model". The spec notes that LOD 300 elements are not necessarily clash-free; they are modeled at accurate size so you can judge the space they take. If you plan to run clash detection in Navisworks between new and existing work, LOD 300 is the floor, and LOD 350 is where coordination becomes reliable.

Scan to BIM LOD 350

LOD 350 exists because coordination needs more than measured elements: it needs to know where they meet. BIMForum notes that it usually requires craft knowledge. On a scan, apply it to rooms where it pays, such as mechanical rooms and congested corridors, not to the whole building.

LOD 400 from a scan

The spec describes LOD 400 as the level of shop drawings and notes that most models contain few if any LOD 400 elements. A laser scanner captures surfaces, not part numbers or weld details. If a fabricator needs LOD 400, the scan gives them the measured envelope to fit into; the detail comes from their own shop drawings.

What a laser scanner cannot see caps the LOD

A terrestrial laser scanner records the surfaces in its line of sight. Everything else is inferred, and an inferred element cannot honestly carry an LOD 300 label for location. Before you set the matrix, check what the scan will actually see.

  • Inside walls: studs, conduit, plumbing and blocking are not captured. Wall assemblies are modeled from measured thickness; the build-up is assumed or taken from drawings.
  • Above hard ceilings: drywall ceilings hide everything above. Lay-in grid ceilings can be scanned above only if tiles are lifted, which takes time and access approval.
  • Roofs: an interior scan sees the underside of the deck and the joists; the roof surface, parapets and rooftop units need setups on the roof.
  • Behind equipment and stored goods: racking, inventory and furniture block the scanner. Occupied buildings have gaps unless spaces are cleared.
  • Underground and in-slab: under-slab plumbing and in-slab conduit are invisible to a laser.

Where an element is hidden, the honest options are to leave it out, model it at LOD 200 from drawings and label it as such, or open it up and scan again. Ask any provider which they will do. Our guide to point cloud file formats explains how to get the registered cloud itself, so your team can check coverage before modeling starts.

LOD is not accuracy: add an LOA line to the scope

LOD says what is modeled and how far it is developed. It does not say how close the model is to the real building. That is a separate requirement, and the BIMForum spec points to the USIBD Level of Accuracy (LOA) Specification, now at version 3.1, for it. The LOA uses five levels, LOA10 to LOA50, from coarsest to tightest, and version 3.1 adds a section on specifying tolerances with standard deviation. In practice, write two lines for each element group: the LOD, and the LOA you need it at. Ask for the measured accuracy of the point cloud as well, since the model cannot be more accurate than the scan under it.

For scale: Sonoran 3D Scanning's typical scan accuracy is ±2 to 6 mm at typical working ranges, depending on scanner, range and conditions. Our deliverables are informational and non-certified. If you need certified measurements, use an Arizona-registered land surveyor.

LOD matrices for two Phoenix building types

Much of the commercial stock around Phoenix and Maricopa County falls into a few repeating types. Two of them show how the matrix changes with the building. Both examples are illustrative, not projects we completed.

Tilt-up concrete warehouse being converted to offices

Tilt-up concrete wall panels, a steel joist and joist girder roof on columns, a metal deck, and rooftop units. The design work is new offices inside the shell and new mechanical on the roof.

ElementLODWhy
Tilt-up panels, openings, dock doors300New openings will be cut; panel joints and sizes matter
Columns and joist girders300New partitions and ceilings work around them
Open-web joists300 as a measured patternSpacing and depth set the new ceiling height
Roof deck, drains, rooftop units300 deck, 200 unitsNew units need structure and clearance; existing ones only a footprint
Slab, trenches, pits300Slab level controls new plumbing routes

1970s-80s strip retail center, tenant improvement

CMU demising walls, storefront glazing, a bar-joist roof and a lay-in ceiling, with years of past tenant changes that no drawing records. The design work is one or two suites.

ElementLODWhy
Suite walls, storefront, doors300The new layout is drawn against them
Neighboring suites200 or excludedContext only
Ceiling height and grid300 height, 200 gridCeiling height drives the new design; grid is replaced
Above-ceiling ducts200, or 350 if tiles are liftedOnly modeled as well as the scan sees them
Exterior facade300 for the suite frontageSignage and storefront changes need it

When a tenant improvement needs a City of Phoenix permit, the permit drawings are prepared and submitted by your architect or design professional. A scan to BIM model is the measured base they work from, not a permit document by itself.

How the LOD moves cost and schedule

Higher LOD means more modeling hours, and LOD 350 adds time wherever it applies. The cheapest way to cut a scan to BIM budget is not to drop the whole model to LOD 200, but to limit LOD 300 and 350 to the areas you will change. A second lever is the scan itself: it should be planned for the highest LOD you will ever need, because going back to site costs more than a few extra setups. Raising the LOD later is possible if the cloud covers the elements, but it means revisiting each element.

For what drives the total price, see our guide to 3D laser scanning cost. For a number on your building, our page on scan to BIM in Phoenix lists what we need to quote, or you can send the building and your LOD matrix for a quote.

What to write in a scan to BIM scope

  1. What the model is for: design, coordination, facility management, or leasing. The purpose decides most of the matrix.
  2. The LOD matrix: LOD per element group and area, not one number for the building.
  3. The accuracy: an LOA per element group, plus the measured accuracy of the point cloud.
  4. Exclusions: concealed elements, minimum pipe and duct size, furniture, and what happens where the scan cannot see.
  5. Model setup: Revit release, template, levels, worksets, and whether you need an IFC or an AutoCAD DWG export.
  6. The point cloud: registered, in the format your team can open, delivered with the model so anyone can check one against the other.

Frequently asked questions

What does BIM LOD stand for?

LOD stands for level of development: the degree to which an element's geometry has been thought through, and so how far the project team may rely on it. People also read it as level of detail, but the BIMForum LOD Specification uses level of development. A very detailed element that is placed in the wrong spot is still only LOD 200.

What LOD is best for scan to BIM?

For renovation design and most tenant improvements, LOD 300 for the elements you will design against, and LOD 200 for the rest. Add LOD 350 only where new systems must be coordinated with existing ones, such as a mechanical room or a congested ceiling. LOD 400 is rarely worth asking for from a scan, because a scanner does not see fabrication detail.

What is the difference between LOD 300 and LOD 350?

At LOD 300 an element's quantity, size, shape, location and orientation can be measured from the model. LOD 350 adds its interfaces with adjacent elements, such as where a beam bears on a column or where a duct passes through a wall. LOD 350 is meant for construction-level coordination.

Is LOD 500 higher than LOD 400?

No. The 2025 BIMForum LOD Specification says LOD 500 does not indicate a higher level than LOD 400. It means the element's geometry comes from observing an existing item rather than designing a future one, and its accuracy must be stated, for example with the USIBD Level of Accuracy specification.

Does a point cloud have an LOD?

No. LOD describes modeled elements. A registered point cloud is measurement data: it has an accuracy, not a level of development. The model built from it gets an LOD per element.

What is the difference between CAD to BIM and scan to BIM?

CAD to BIM rebuilds a model from existing 2D drawings, so it inherits whatever errors and missing changes those drawings carry. Scan to BIM models the building from a laser scan of what is actually there. For an older building whose plans no longer match the site, scan to BIM is the safer base.

How much does scan to BIM cost?

It depends on floor area, the LOD per element, the disciplines modeled, access and deadline. Most commercial scanning projects we quote in Phoenix range from $2,500 to $15,000, with a detailed quote before any work starts.

Need a fee and a scan date for your Phoenix project?

Send the address, square footage and the deliverables you need. We reply within one business day with a scope and a quote.

Request a QuoteCall (520) 800-5310

Request a 3D scanning quote

Phoenix metro · reply within one business day

Deliverables needed

We reply within one business day. Prefer the phone? (520) 800-5310